Ballast-water treatment, records and failures

RISQ 5.10Section 5 · Pollution Prevention and ControlSource marking: V

Applicability: Apply the vessel, equipment and operational conditions stated in this entry.

What is being checked

The approved ballast plan is followed and treatment performance is verified.

Ready on board

0 / 12 checked

Check the vessel’s actual procedures, equipment and records against these points from RISQ 3.2.

Practice questions

Preparation prompts derived from this entry, not an official inspector interview script.

1What does repeated high TRO during discharge suggest?

Possible ineffective neutralisation. The source lists metering-pump, neutraliser preparation/quantity, TRO sampling/reagent and valve-arrangement problems.

2Can a failed system simply be bypassed to finish deballasting?

No. The PDF calls for contacting management first, treating bypass as a last resort, addressing environmental risk and following the failure/notification arrangements.

3What distinguishes an electronic BWRB from an unapproved electronic log?

The ship carries the required ship-specific declaration for the approved replacement system.

Where a finding may arise

Missing evidence, defects or operation inconsistent with the arrangements described above may prevent a satisfactory answer. These are preparation concerns derived from the question, not reported past observations.

Past observations for practice

Anonymised reports, manually reviewed before publication. These are reported experiences, not additional inspection requirements.

No reviewed observations have been added for this entry.

Share an observation for private review

Remove vessel, company and inspector names, report numbers, exact dates and confidential information. Do not paste a complete inspection report.

Source clarification

The PDF makes broad statements about “all ships” and the September 2024 D-2 milestone. This entry does not use those statements to remove vessel-specific Convention applicability, approved arrangements or exemptions. Exchange is not presented as automatic permission to bypass required treatment.

References and source status

RightShip Inspection Ship Questionnaire, November 2025, version 3.2. Section 5, page 73–74, reference 5.10.

The explanation, checklist and practice answer derive from the supplied questionnaire. Reported observations are separately contributed and manually reviewed; they are not official RISQ guidance.

Independent DeepDraft preparation guide, based on the supplied RISQ 3.2 questionnaire. Not an official RightShip product or inspection report.