Maritime analysis. Real-time insight.

RightShip Guide

THE DEEPDRAFT · RIGHTSHIP PREPARATION

Alcohol-compatible firefighting systems

RISQ 7C.4Section 7C · Fuel Management (Alternative Fuel: Methanol)Source marking: V

Applicability: Section 7C applies where equipment, machinery or a system on board uses methyl/ethyl alcohol fuel. Apply the vessel-specific conditions in this entry.

What is being checked

Fire protection is suitable for alcohol fuel and crew know its use.

Ready on board

0 / 6 checked

Check the vessel’s actual procedures, equipment and records against these points from RISQ 3.2.

Practice questions

Preparation prompts derived from this entry, not an official inspector interview script.

1Can the extinguishing medium be selected without considering the fuel?

No. The source requires suitability for methyl/ethyl-alcohol fires and specifies alcohol-resistant foam arrangements for the listed areas.

2Which deck area must the tank foam protection cover?

The area below the open-deck fuel tank where a spill could spread.

Where a finding may arise

Missing evidence or defects inconsistent with the checks above may prevent a satisfactory answer. These are preparation concerns derived from the question, not explicit additional finding criteria or reported past observations.

Past observations for practice

Anonymised reports, manually reviewed before publication. These are reported experiences, not additional inspection requirements.

No reviewed observations have been added for this entry.

Share an observation for private review

Remove vessel, company and inspector names, report numbers, exact dates and confidential information. Do not paste a complete inspection report.

Source clarification

The PDF also quotes a 2021 whitepaper discussing small-fire dry chemical/CO2, dilution with water of at least four times the pool volume, and recommended alcohol-resistant film-forming foam for larger pools. That simplified comparison is not a shipboard attack plan or a universal water-application instruction. Use the approved firefighting system and fuel-handling manual; no foam concentration or application rate is invented here.

References and source status

RightShip Inspection Ship Questionnaire, November 2025, version 3.2. Section 7C, page 98–99, reference 7.4.

The explanation, checklist and practice answer derive from the supplied questionnaire. Reported observations are separately contributed and manually reviewed; they are not official RISQ guidance.

Independent DeepDraft preparation guide, based on the supplied RISQ 3.2 questionnaire. Not an official RightShip product or inspection report.